中文版英文版

Electric fence system push case
| | | Release time: 2022-07-20 17:07:07 | Hits
share:

The electric fence system is to set pulse electric fence detectors in the surrounding area of the exit channel to form the prevention and management of the entrance of the electric fence. The electric fence system is the second and most important line of defense.

Responsible for safety and security. When there is a way to climb over the fence or damage, the detector can transmit the alarm information to the management, which receives and processes the alarm signal, and the area of invasion is displayed on the map of the area that pops out of the computer; At the same time, the external audible and visual alarm starts to alarm; At the same time, it is linked with the monitoring system to jump out of the real-time picture of the invaded area on the monitoring screen; The middle guard on duty informed the security guard on patrol to rush to the scene at once.

The security guard will restore the alarm state of the alarm host and detector after handling on site.

At the same time, the on-site alarm can also alarm with an alarm signal to remind the nearby staff to pay attention and assist the security guard.

★ system functions

◆ there is a strong deterrent action, which can effectively resist and retreat the invaders, protect the surrounding area, and provide timely alarm for crossing

◆ strong adaptability, good anti false alarm performance and good prevention effect

◆ give an alarm on site to stop the invaders and cause the employees to pay attention to prevention

◆ the system zoning management facilitates the accurate positioning of the alarm area

◆ Zhong Fang alert information is intuitive, such as warning signal, electric map and so on.

◆ linked monitoring image alarm, linked night monitoring auxiliary light source

◆ realize the state control of front-end equipment through

◆ safe and reliable, direct injury to the body.

★ introduction to electric fence gt-2008 

GT-2008, compared with traditional fence products, has achieved a breakthrough in technology and is also the most advanced fence product in China before.
 
The main advantages are as follows: 

◆ the unique GT technology can realize electric shock on each wire on the front fence, so that the intruder can ride.

◆ it has led display function, which can directly display the working state on the fence of the power supply on the host board.

◆ LCD display, which can display the actual voltage value of each line in real time.

◆ it has the function of switching from low pressure to low pressure, which can not only block the operation of alarm, but also reduce the degree of blow at the same time, and increase the degree of blow at night in the low pressure mode.

◆ the host can be directly equipped with batteries to facilitate management.

◆ through the external keyboard, the operating state of the host can be set and adjusted remotely, which has a more personalized design. 

★ Main Features of Shear-proof Fence Host

◆ Differential Voltage Output Technology: There is a voltage pulse on each line and a pressure difference between adjacent lines.

◆ the host has the alarm functions of short circuit, disconnection, disassembly and shearing prevention, and the alarm function of communication failure;

◆ Host has Voltage mode and Low Voltage mode, and can be switched in and out by PC software or keyboard, or by switching switches locally in the host.

◆ the host has a remote control function, which can carry out pressure deployment, low-voltage deployment and defense removal operations on the host through the remote controller, and raise the alarm signal whether the deployment and defense removal operation is successful;

◆ the host has the functions of adjustable output voltage and adjustable output energy to adapt to different field environments;

◆ With 485 bus control mode, remote centralized control management can be achieved through GT-SK678 keyboard, PC software, PC software windowboard, etc.

◆ the host site can set the deployment status, time, defense area code, alarm delay, alarm number delay, etc., which is convenient and fast;

◆ the host has battery voltage protection function to prevent short circuit.

★ basic technical parameters: 

Peak value of positive and negative voltage output to ground 

5kV

Positive and negative low voltage output peak

<1 .0KV

Output peak current

≤10A

Pulse duration

≤0 . 1s

Pulse interval time

1 .0s

Overall system power consumption

≤15W

Single pulse output energy

≤5 .0J

Single pulse output power

2 .5mC

Battery backup time

≥ 8 ⼩ (output 6.0KV) 

Alarm signal

Rated voltage 12V, maximum power 15W 

★ main characteristics of intelligent pulse electric fence host

◆ differential voltage output technology: there is voltage on each line and voltage difference between adjacent lines.

◆ Low/low voltage switching, remote device switching.

◆ Short circuit, disconnection, anti-disassembly alarm, equipment failure_I detect.

◆ set the alarm delay time by.

◆ The appearance design of anti-collar housing and upper and lower cover guides the development of the industry.

◆ RS485 remote control, keyboard, computer, network and other centralized management cases.

◆ DC12V and normally open / normally closed alarm output.

Basic technical parameters:

Peak output voltage

5KV〜10KV

Output low voltage peak

700〜1000V

Peak power output

<10A

Pulse duration

≤0 . 1s

Pulse interval time

1s〜1 .5s

System power consumption

≤15W

Single pulse output energy

≤5 .0J

Single pulse output power

2 .5mC

 ★ product description of multi-point control remote control keyboard

 

◆ in the same system, 8 keyboards or computers can control the fence host in 8 different places

◆ it can be deployed and disarmed regularly and ⾼ low voltage switching

◆ 1-254 defense areas can be controlled through 485 bus, and fence voltage and various alarm information can be displayed in real time

◆ it can record the last 100 alarm messages

◆ Can be timed cloth to undo, low voltage switching

◆ the keyboard address code can be programmed

◆ the infrared radiation alarm signal can be connected through the bus address module

◆ Cable wiring withdrawal, Low voltage switch, alarm reset